1. Running NeuG standalone device on Windows

    Yesterday (2013-11-13), I gave my niece a NeuG device as a gift.

    But, she is one of victims who can only use PC with Windows. Thus, I tried to find how to use it on the PC in her home.

    INF file is needed

    I realized that the CDC/ACM …

    more »
  2. Running NIST STS 2.1.1 on NeuG True RNG (3)

    NeuG 0.11 was released.

    With standalone NeuG device of FST-01, I gathered 500 files of 125MB (=1,000,000,000 bits, that is for 1,000 samples of 1,000,000-bit sequence).

    Then, I ran the test suite over 500 files, while a single file has 125MB. All parameters …

    more »
  3. Running NIST STS 2.1.1 on NeuG True RNG (2)

    NeuG 0.05 was released, and I have a USB memory which says "64GB" capacity. This USB memory is a bit bigger than the one I used, and it can have 500 files of 125MB (=1,000,000,000 bits, that is for 1,000 samples of 1,000,000-bit …

    more »
  4. Running NIST STS 2.1.1 on NeuG True RNG

    In papers, we can see people use NIST STS test suite to evaluate RNG.

    However, I think that many people just evaluate short sequences, less samples, or only for several times (most are just a single time).

    Perhaps, it is because people have tendency to report "SUCCESS", not facts.

    Well …

    more »